Estudio de validación de un instrumento de evaluación postural (SAM, spinal analysis machine)
Validation of a spinal analysis machine
Visits
...
Ángela Olarua, Joan Parra Farréb, Ramon Baliusc
a DC, BSc, South Western University of Health Sciences. Alumna de postgrado de la Universitat Internacional de Catalunya (UIC).
b Leitat.
c Consell Català de l'Esport. Barcelona. Clínica F. FIATC.
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Figures (2)
Tables (2)
Tabla 1. Reproductibilidad de las mediciones de un mismo observador (cómo varía el resultado cuando un mismo observador valora un mismo voluntario)
Tabla. II Reproductibilidad de las mediciones de otro observador (cómo varía el resultado cuando otro observador valora un mismo voluntario)
Show moreShow less
Introducción: La postura bípeda está controlada por el sistema nervioso central, que recluta articulaciones, ligamentos, tendones y músculos especializados, asegurando una oscilación corporal y un gasto energético mínimos. El desequilibrio postural genera contracciones musculares compensatorias que alteran la biomecánica corporal y producen cambios degenerativos precoces y lesiones de sobrecarga, especialmente en la población practicante de deporte. Los chequeos posturales frecuentes podrían detectar alteraciones y ayudar en la prevención de sus consecuencias duraderas. Objetivo: Valorar la fiabilidad intra e y interobservador del instrumento de evaluación postural SAM (spinal analysis machine), que consta de una estructura metálica con dos balanzas para los pies, dos cintas métricas, un hilo vertical y tres horizontales para medir la inclinación lateral del cuerpo y la altura de los mastoides, los hombros y las crestas ilíacas. Sujetos y métodos: Participaron 21 jugadoras de baloncesto con edades comprendidas entre los 14 y los 15 años, y 2 examinadores que hicieron 2 mediciones con un intervalo de 7 días. Para el análisis estadístico se utilizó la prueba de la t de Student para variables numéricas apareadas y para el estudio de las varianzas se usó el ANOVA. Resultados: En el análisis intraobservador no hubo diferencia significativa entre las dos lecturas (p < 0,05); en el interobservador hubo una diferencia significativa entre las lecturas de los parámetros horizontales pero no se encontró diferencia significativa entre las mediciones de la distribución de peso y de la inclinación lateral del cuerpo (p < 0,05). Conclusión: Considerando la fiabilidad intraobservador y su coste relativamente bajo, la SAM se puede utilizar clínicamente para valorar la postura estática antes y después de intervenciones terapéuticas y para estudios longitudinales.
Palabras clave:
Postura
Biomecánica
Fiabilidad
Evaluación postural
Introduction: Standing posture is controlled by the central nervous system, which relies on the recruitment of joints, ligaments, tendons, and specialized muscles to ensure minimum body oscillation and energy expenditure. Postural imbalance induces compensatory muscle contraction resulting in alteration of body biomechanics and a predisposition to early degenerative changes and overuse injuries, especially among the population practicing sports. Frequent postural screenings could detect alterations and help to prevent often life-long consequences. Objective: To assess the intra- and interobserver reliability of the spinal analysis machine (SAM), a simple portable postural screening instrument, consisting of a rectangular metal frame with bilateral electronic scales, two vertical measure tapes, and one vertical and three horizontal strings, measuring lateral body sway and the height of mastoids, shoulders and iliac crests. Subjects and methods: Participants were 21 female basketball players aged between 14 and 15 years. Measurements were conducted by two observers, and were repeated after 7 days. Statistical analysis was performed using a paired Student's t- test for repeated measures and analysis of variance (ANOVA) to assess reliability. Results: Analysis of intraobserver reliability showed no significant differences between the two measurements in any of the parameters ( P<.05). Analysis of interobserver reliability revealed a significant difference between the measurements of horizontal parameters but no significant differences between the measurements of lateral body sway and bilateral weight distribution ( P<.05). Conclusion: Given the intraobserver reliability and the relatively low cost of the SAM, this instrument could be clinically useful to screen static posture before and after therapeutic procedures. It could also be useful in longitudinal studies.
Keywords:
Posture
Biomechanics
Reliability
Spinal analysis

Article

These are the options to access the full texts of the publication Apunts Sports Medicine
Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Subscribe
Subscribe to

Apunts Sports Medicine

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
Email
Apunts Sports Medicine

Subscribe to our newsletter

Article options
Tools

Are you a health professional able to prescribe or dispense drugs?